LingoScholarLiterature. Evidence. Research.
Research programmes
Open studyCatalogueAcademic access
Return to the research atlas
Public research reference
2003Canadian Journal of Civil Engineering

The effect of end distance on the moment resistance of timber rivet connections

J A Hampson; H G.L Prion; F Lam

GLT / GlulamLVLConnectionsMaterial propertiesDesign methodsExperimental
Open publisher page
01 / From the publisher

Abstract

The results of an experimental study on moment connections with timber rivets are reported. The end distance for a four-rivet moment connection is varied in an attempt to determine the effect on the moment capacity and the failure mode. Varying the end distance did not seem to induce the occurrence of a brittle failure mode, but a slight reduction in the strength and stiffness of joint was observed. This was confirmed for specimens made with glued-laminated timber (glulam), laminated-veneer lumber (LVL), and parallel-strand lumber (PSL).Key words: wood, timber, moment, connection, brittle, end distance, glulam and rivet.

02 / Cite this paper

Reference

J A Hampson; H G.L Prion; F Lam. (2003). The effect of end distance on the moment resistance of timber rivet connections. Canadian Journal of Civil Engineering. https://doi.org/10.1139/l03-050

Explore the literature

Follow references, discover citing works and find related studies.