Development of an Innovative Composite Steel and Cross Laminated Timber Floor System
Abstract
<p>This paper presents the results from a major research programme that investigated an innovative composite steel and cross laminated timber (CLT) floor system for low-, medium- and high-rise office developments. In total, 21 push tests were completed to investigate the effect of several key variables on the load-slip behaviour of the shear connectors, including the stud spacing, gap between the CLT panels, and the transverse reinforcement bars. Based on the optimum shear connector arrangement determined from the push tests, a 12.0 m composite steel and CLT beam has been constructed at full-scale and will be load tested to failure at the University of Warwick. The tests demonstrate that the shear connectors easily satisfied the Eurocode 4 requirements for ‘ductile’ connectors, which permits the use of partial shear connection theory to be applied in design using this technology.</p>
Reference
Stephen J. Hicks; Andrew Woodward; Waleed Hamad. (2025). Development of an Innovative Composite Steel and Cross Laminated Timber Floor System. IABSE Reports. https://doi.org/10.2749/tokyo.2025.1919