Fire performance of gusset connections in glue‐laminated timber
Abstract
Abstract This paper describes a comprehensive experimental investigation of the fire performance of nailed gusset connections between large glue‐laminated timber members. Both plywood and steel gusset plates were investigated with a range of loaded and unloaded test methods. The principal conclusions are that unprotected gussets have poor fire performance, but that a layer of solid wood or gypsum plasterboard will provide at least one hour of fire protection to typical joints.
Reference
Andrew H. Buchanan; Andrew B. King. (1991). Fire performance of gusset connections in glue‐laminated timber. Fire and Materials. https://doi.org/10.1002/fam.810150306
Explore the literature